General Information
Type de prestataire
Laboratoire d'essais
Adresse postale physique
OFF MNAZI MOJA ROAD
Mombasa
Kenya
Numéro de téléphone
+254714 323 930
E-mail
admin [at] inspectorate-ea.com
Site web
Statut juridique
Privé
Le laboratoire a-t-il été accrédité dans une quelconque portée ?
Oui
Portée de l'accréditation
i. Determination of density for automotive Gas Oil in accordance with ASTM D 1298 [Measurement range : 0.6000 to 1.2500kg/L]
ii. Determination of distillation for automotive Gas Oil at atmospheric pressure in accordance with ASTM D 86 [Measurement range : 36 to 4000C]
iii. Determination of Flash point for automotive Gas Oil in accordance with ASTM D 93 [Measurement range : 19 to 4000C]
ii. Determination of distillation for automotive Gas Oil at atmospheric pressure in accordance with ASTM D 86 [Measurement range : 36 to 4000C]
iii. Determination of Flash point for automotive Gas Oil in accordance with ASTM D 93 [Measurement range : 19 to 4000C]
Organisme d'accréditation
a) Accreditation body-KENAS [Kenya Accreditation Service]
b) Reference number for certificate of accreditation : TL/44
b) Reference number for certificate of accreditation : TL/44
Le laboratoire dispose-t-il d'autres sites ?
Non
Personnel
Chief Executive Officer (CEO) / Head of Organization
Nom du PDG
KYALO ILUNGA
Téléphone du PDG
Courriel du PDG
kyalo [at] inspectorate-ea.com
Total laboratory personnel
Total du personnel de laboratoire
7
Personnel de laboratoire masculin
6
Personnel de laboratoire féminin
1
Technical personnel
Total personnel technique
3
Personnel technique masculin
3
Personnel technique féminin
0
Technical Information
Testing
Services de laboratoire offerts
Chimie
Eau / Alimentation
Portée des services offerts
Objet ou produit testé ou matrices
Automotive Gas Oil
Paramètre d'essai/ propriétés mesurées
Appearance/Color
Kinematic Viscosity @ 40°C cSt
Copper strip corrosion, 3 hrs at 50°C (*)
Cetane index (Calculated)
Cloud point °C
Cold filter plugging point (CFPP) °C
Sediment % m/m
Water content, mg/kg
Ash %m/m (*)
Sulphur content, mg/kg
Carbon residue on 10% volume fraction
Neutralization value:
Strong acid No. mg KOH/g
Total acid no. mg KOH/g
Kinematic Viscosity @ 40°C cSt
Copper strip corrosion, 3 hrs at 50°C (*)
Cetane index (Calculated)
Cloud point °C
Cold filter plugging point (CFPP) °C
Sediment % m/m
Water content, mg/kg
Ash %m/m (*)
Sulphur content, mg/kg
Carbon residue on 10% volume fraction
Neutralization value:
Strong acid No. mg KOH/g
Total acid no. mg KOH/g
Type de test/instrumentation utilisé
Viscometric
Volatility
Spectrometry
Volatility
Spectrometry
Méthodes
Visual
ASTM D 445 IP 71
ASTM D 130 IP 154
ASTM D 976
ASTM D 2500
IP 309
ASTM D 473 IP53
ASTM D 95
ASTM D 482
ASTM D 4294
ASTM D 189 IP13
ASTM D 974
ASTM D 445 IP 71
ASTM D 130 IP 154
ASTM D 976
ASTM D 2500
IP 309
ASTM D 473 IP53
ASTM D 95
ASTM D 482
ASTM D 4294
ASTM D 189 IP13
ASTM D 974
Statut d'accréditation
Non
Objet ou produit testé ou matrices
Automotive Gas Oil
Paramètre d'essai/ propriétés mesurées
Distillation:
Initial Boiling Point, °C
10% evaporated at, °C
50% evaporated at, °C
90% evaporated at, °C
Final Boiling Point, °C
Density
Flash point (Pensky martens)
Initial Boiling Point, °C
10% evaporated at, °C
50% evaporated at, °C
90% evaporated at, °C
Final Boiling Point, °C
Density
Flash point (Pensky martens)
Type de test/instrumentation utilisé
Volatility
Gravimetric
Gravimetric
Méthodes
ASTM D 86
ASTM D 1298 IP 160
ASTM D 93
ASTM D 1298 IP 160
ASTM D 93
Statut d'accréditation
Oui
Objet ou produit testé ou matrices
JET A-1
Paramètre d'essai/ propriétés mesurées
Appearance
Odour
Density @ 15 °C
Density @ 20 °C
Electrical Conductivity
Flash Point
Total Sulphur
Distillation
Initial Boiling Point
10% vol. Rec. at
50% vol. Rec. at
90% vol. Rec. at
Final Boiling Point
Total Recovery
Residue
Loss
Odour
Density @ 15 °C
Density @ 20 °C
Electrical Conductivity
Flash Point
Total Sulphur
Distillation
Initial Boiling Point
10% vol. Rec. at
50% vol. Rec. at
90% vol. Rec. at
Final Boiling Point
Total Recovery
Residue
Loss
Type de test/instrumentation utilisé
Gravimetric
Volatility
Spectrometry
Volatility
Spectrometry
Méthodes
Visual
Organoleptic
ASTM D 1298
ASTM D-2624
ASTM D 93
ASTM D 4294
ASTM D-86
Organoleptic
ASTM D 1298
ASTM D-2624
ASTM D 93
ASTM D 4294
ASTM D-86
Statut d'accréditation
Non
Objet ou produit testé ou matrices
Fuel Oil
Paramètre d'essai/ propriétés mesurées
Density @ 20°C (Kg/l)
Kinematic Viscosity @ 50° cSt
Flash point (Pensky martens)
Sulphur Content, % wt
Water Content, % vol
Sediments by extraction, % m/m
Pour Point, oC
Carbon Residue (Conradson), % m/m
Gross Calorific Value, MJ/Kg
Ash content, % m/m
Sodium Content, ppm
Vanadium Content, ppm
Aluminium + Silicon, mg/Kg
Asphaltenes % m/m
Kinematic Viscosity @ 50° cSt
Flash point (Pensky martens)
Sulphur Content, % wt
Water Content, % vol
Sediments by extraction, % m/m
Pour Point, oC
Carbon Residue (Conradson), % m/m
Gross Calorific Value, MJ/Kg
Ash content, % m/m
Sodium Content, ppm
Vanadium Content, ppm
Aluminium + Silicon, mg/Kg
Asphaltenes % m/m
Type de test/instrumentation utilisé
Gravimetric
Viscometric
Volatility
Spectrometry
Viscometric
Volatility
Spectrometry
Méthodes
ASTM D 1298
ASTM D 445
ASTM D 93
ASTM D 4294
ASTM D 95
ASTM D473
ASTM D 97
ASTM D 189
ASTM D 4868
ASTM D482
IP 288
IP 288
ASTM D5184
IP 143
ASTM D 445
ASTM D 93
ASTM D 4294
ASTM D 95
ASTM D473
ASTM D 97
ASTM D 189
ASTM D 4868
ASTM D482
IP 288
IP 288
ASTM D5184
IP 143
Statut d'accréditation
Non
Objet ou produit testé ou matrices
MOGAS
Paramètre d'essai/ propriétés mesurées
Appearance
Water content, mg/kg
Color
Odour
Density at 20 °C, g/ml
Benzene content, % v/v
Oxygenates
Research Octane Number, RON
Distillation:
Initial Boiling Point, °C
10% evaporated at, °C
50% evaporated at, °C
90% evaporated at, °C
Final Boiling Point, °C
Residue per cent v/v
Recovery @ 70 Deg. C, % vol.
Reid Vapor Pressure@37.8°C, kPa
Fuel Volatility Index (FVI)
Lead Content mg/l
Copper corrosion, 3 Hrs at 50°C ratingSulphur content, % mmExistent gum (solvent washed mg/100 ml)
Oxidation stability, min
Doctor test OR Mercaptan Sulphur, % mm
Water content, mg/kg
Color
Odour
Density at 20 °C, g/ml
Benzene content, % v/v
Oxygenates
Research Octane Number, RON
Distillation:
Initial Boiling Point, °C
10% evaporated at, °C
50% evaporated at, °C
90% evaporated at, °C
Final Boiling Point, °C
Residue per cent v/v
Recovery @ 70 Deg. C, % vol.
Reid Vapor Pressure@37.8°C, kPa
Fuel Volatility Index (FVI)
Lead Content mg/l
Copper corrosion, 3 Hrs at 50°C ratingSulphur content, % mmExistent gum (solvent washed mg/100 ml)
Oxidation stability, min
Doctor test OR Mercaptan Sulphur, % mm
Type de test/instrumentation utilisé
Volatility
Gravimetric
Volatility
Spectrometry
Gravimetric
Volatility
Spectrometry
Méthodes
ASTM D 4176
ASTM D 95
Visual
Organoleptic
ASTM D 1298 IP 160
ASTM D 4420 IP 429
ASTM D 5599
ASTM D 2699
ASTM D 86
ASTM D 323
Calculation
IP 429 ASTM D 3237
ASTM D 130
ASTM D 4294
ASTM D 381
ASTM D525
ASTM D 4952 IP/30
ASTM D 3227
ASTM D 95
Visual
Organoleptic
ASTM D 1298 IP 160
ASTM D 4420 IP 429
ASTM D 5599
ASTM D 2699
ASTM D 86
ASTM D 323
Calculation
IP 429 ASTM D 3237
ASTM D 130
ASTM D 4294
ASTM D 381
ASTM D525
ASTM D 4952 IP/30
ASTM D 3227
Statut d'accréditation
Non
Objet ou produit testé ou matrices
Other liquid petroleum products: Illuminating kerosene,
Wheat
Wheat
Paramètre d'essai/ propriétés mesurées
Moisture contents
Type de test/instrumentation utilisé
Gravimetric
Méthodes
ISO 712
Statut d'accréditation
Non
Le laboratoire procède-t-il à l'échantillonnage, à la demande du client, des produits à tester ?
Oui
Proficiency Testing
Le laboratoire participe-t-il à des essais d'aptitude pour les portées accréditées ?
Oui
Le laboratoire participe-t-il à des essais d'aptitude pour des champs d'application non accrédités ?
Oui
Détails du régime PT
Service provider : SABS
Inspectorate East Africa Ltd Laboratory : Lab number 06 in the
proficiency testing scheme
Product for PT scheme: Automotive Diesel Fuel :
Scope/Test parameters :
Cetane Index
Cetane No.
Cold filter plugging point,0C
Cloud Point
Kinematic Viscosity at 400C, mm2/s
Carbon residue on 10% volume fraction Flash point ( PMCC) 0C
Density at 200C,kg/L
Sulphur content, mg/kg
Water content, mg/kg
Distillation :
Initial boiling point 10% (v/v) recovered 50% (v/v) recovered 90% (v/v) recovered 95% (v/v) recovered
To-date we have participated in a total of 8 MAP [Measurement Assurance Program] RUNS
Year 2017 :MAP RUN 105 & 106
Year 2018 :MAP RUN 107,108 &110 Year 2019 : MAP RUN 111,112 & 113
A total of 26 laboratories participating in MAP RUN Scheme [AGO]
A brief program on the scheme :
MAP RUN: 100
Sample from supplier[SA BS]: 16/02/19
Samples from SABS to participants: 02/03/19
Results due from participants:13/04/19
Final results due from SABS to participants:25/05/19
IRQ due from participants to SABS: 08/06/19
Inspectorate East Africa Ltd Laboratory : Lab number 06 in the
proficiency testing scheme
Product for PT scheme: Automotive Diesel Fuel :
Scope/Test parameters :
Cetane Index
Cetane No.
Cold filter plugging point,0C
Cloud Point
Kinematic Viscosity at 400C, mm2/s
Carbon residue on 10% volume fraction Flash point ( PMCC) 0C
Density at 200C,kg/L
Sulphur content, mg/kg
Water content, mg/kg
Distillation :
Initial boiling point 10% (v/v) recovered 50% (v/v) recovered 90% (v/v) recovered 95% (v/v) recovered
To-date we have participated in a total of 8 MAP [Measurement Assurance Program] RUNS
Year 2017 :MAP RUN 105 & 106
Year 2018 :MAP RUN 107,108 &110 Year 2019 : MAP RUN 111,112 & 113
A total of 26 laboratories participating in MAP RUN Scheme [AGO]
A brief program on the scheme :
MAP RUN: 100
Sample from supplier[SA BS]: 16/02/19
Samples from SABS to participants: 02/03/19
Results due from participants:13/04/19
Final results due from SABS to participants:25/05/19
IRQ due from participants to SABS: 08/06/19
Le laboratoire sous-traite-t-il les essais à d'autres laboratoires ?
Oui
Services externalisés
A total of four participants :
Inspectorate East Africa Limited Laboratory-Accredited by
KENAS ref TL/44
SGS-Accredited by KENAS
Intertek Testing services (EA) (Pty) Ltd-Accredited by KENAS
as TL/46 KPRL-Accredited by SANAS
The above laboratories are ISO/IEC 17025:2005 accredited under
various scope
The scheme covers the following products :
Gasoil Mogas Jet A-1 Fuel Oil
Scheme program : Quarterly
First quarter-January-Jet A-1
Second quarter-April ,Product: Gasoil
Third quarter-July ,Product :Mogas
Fourth quarter-October ,Product : Fuel Oil
Year 2019 Runs :
08th January 2019: JET A-1 :Reference-Insp/02/Jan/19 03rd April 2019- Gasoil : Reference- Insp/01/Apr/19
Supplier of sample (s) : Inspectorate East Africa Ltd Laboratory
Program dates for the subject scheme includes :
Date when the sample will be distributed by IEA to other three participants
Results from participants
Date (s) on when the final results shall be issued to participants
upon analysis.
Inspectorate East Africa Limited Laboratory-Accredited by
KENAS ref TL/44
SGS-Accredited by KENAS
Intertek Testing services (EA) (Pty) Ltd-Accredited by KENAS
as TL/46 KPRL-Accredited by SANAS
The above laboratories are ISO/IEC 17025:2005 accredited under
various scope
The scheme covers the following products :
Gasoil Mogas Jet A-1 Fuel Oil
Scheme program : Quarterly
First quarter-January-Jet A-1
Second quarter-April ,Product: Gasoil
Third quarter-July ,Product :Mogas
Fourth quarter-October ,Product : Fuel Oil
Year 2019 Runs :
08th January 2019: JET A-1 :Reference-Insp/02/Jan/19 03rd April 2019- Gasoil : Reference- Insp/01/Apr/19
Supplier of sample (s) : Inspectorate East Africa Ltd Laboratory
Program dates for the subject scheme includes :
Date when the sample will be distributed by IEA to other three participants
Results from participants
Date (s) on when the final results shall be issued to participants
upon analysis.
Politiques, procédures et registres documentés pour la qualification, l'évaluation et la surveillance de tous les prestataires d
Non
Quality Control / Quality Management
Le laboratoire dispose-t-il d'un système interne de contrôle de la qualité (CQ) pour garantir la qualité des résultats des tests
Oui
Le laboratoire dispose-t-il d'un système de gestion (ou système de gestion de la qualité) pour garantir la qualité des résultats
Oui
Le système est-il documenté dans un manuel qualité ?
Oui