General Information
Tipo de proveedor de servicios
Laboratorio de calibración
DIRECCIÓN POSTAL
Bogota
Colombia
Número de teléfono
+57 8237710
CORREO ELECTRÓNICO
adolfo.rodriguezo [at] metrologica.co
Estatus legal
Privado
¿Ha sido acreditado el laboratorio en algún ámbito?
Sí
Alcance de la acreditación
*Volume (Water Meters)
*Measurement intervals:
-Vn: 1.5 L, measured with flow rates between 2L/h and 50 L/h
-Vn: 3 L, measured with flow rates between 2L/h and 50 L/h
-Vn: 5 L, measured with flow rates between 25 L/h and 100 L/h
-Vn: 10 L, measured with flow rates from 25 L/h to 600 L/h
-Vn: 25 L, measured with flows from 600 L/h to 3000 L/h
-Vn: 50 L, measured with flow rates between 500 L/h to 5000 L/h
-Vn: 100 L, measured with flow rates between 500 L/h to 5000 L/h
*Measurement intervals:
-Vn: 1.5 L, measured with flow rates between 2L/h and 50 L/h
-Vn: 3 L, measured with flow rates between 2L/h and 50 L/h
-Vn: 5 L, measured with flow rates between 25 L/h and 100 L/h
-Vn: 10 L, measured with flow rates from 25 L/h to 600 L/h
-Vn: 25 L, measured with flows from 600 L/h to 3000 L/h
-Vn: 50 L, measured with flow rates between 500 L/h to 5000 L/h
-Vn: 100 L, measured with flow rates between 500 L/h to 5000 L/h
Entidad de acreditación
ONAC
17-LAC-015
17-LAC-015
¿Tiene el laboratorio otras sedes?
No
Personnel
Chief Executive Officer (CEO) / Head of Organization
Nombre del director general
John Jairo Ocampo Serna
Teléfono del director general
Correo electrónico del director general
jjocampo [at] metrologica.co
Total laboratory personnel
Total de personal de laboratorio
17
Personal masculino del laboratorio
9
Personal feminino del laboratorio
8
Technical personnel
Total de personal técnico
7
Personal técnico masculino
5
Personal técnico femenino
2
Technical Information
Fields of Metrology
Otros
Otros servicios de laboratorio de calibración
Volume (water meters)
Alcance de los servicios de calibración ofrecidos
Objeto de calibración
Cold Drinking Water Meters
Ratio (Q3/Q1)
DN15 to DN20
Ratio (Q3/Q1)
DN15 to DN20
Cantidad/ Propiedad
Volume
Referencia al procedimiento
Direct Comparison
Rango/ Límite
-Minimum volume: 1.5 L, measured with flow rates between 2L/h and 50 L/h
-Maximum volume: 100 L, measured with flow rates between 500 L/h to 5000 L/h
-Maximum volume: 100 L, measured with flow rates between 500 L/h to 5000 L/h
CMC
For minimum volume 1.5 l: 0.36%.
For maximum volume 100 L: 0.12%
For maximum volume 100 L: 0.12%
Estado de la acreditación
Sí
Informes sobre la incertidumbre de las mediciones
Sí
How does the laboratory ensure international traceability of its measurements standards?
A través de certificados de calibración emitidos por un laboratorio nacional acreditado
No
A través de certificados de calibración emitidos por un laboratorio extranjero acreditado
Sí
¿Participa el laboratorio en alguna comparación entre laboratorios?
Sí
Por favor, facilite detalles sobre el plan
Proficiency Testing at the level of Assurance of the validity of the results
¿Subcontrata el laboratorio trabajos de calibración a otros laboratorios?
No
Quality Control / Quality Management
¿Opera el laboratorio un sistema de control de calidad interno para garantizar la calidad de las mediciones?
Sí
¿Opera el laboratorio un sistema de gestión (o sistema de gestión de la calidad) para garantizar la calidad de las calibraciones
Sí
¿Está el sistema documentado en un manual de calidad?
Sí